21¼¼±â ÃÊÀÏ·ù È­Çбâ¾÷ (ÁÖ)Çñ½ºÄÍ Ç×»ó ¿©·¯ºÐ°ç¿¡ ÀÖ½À´Ï´Ù.
Á¦Ç°¼Ò°³
¸ôµù¿ë ¿ì·¹Åº
Á¤¹Ð È­ÇÐ
¼ö¿ë¼º ¿ì·¹Åº
¼öºÐ»ê¼º ¿ì·¹Åº
°ÇÃà¿ë Àç·á
¿ì·¹Åº ½Ç¶õÆ®
¿ì·¹Åº ¹æ¼ö¹Ù´ÚÀç
Áö¼öÁ¦
Acrobat ¸®´õ 5.05 (ÇѱÛWin98¿ë) Acrobat Reader,other languages or platforms
Á¦Ç°¸í °³¿ä & Datasheet
HYPER SEAL FSU-300 °í¹«Áö¼öÁ¦¿ë ¿ì·¹Åº ÷°¡Á¦ [1¾×Çü ¼öÆØÀ±¼º Æú¸®¿ì·¹Åº]
HYPER SEAL FSU-390 Åä¸ñ°ø»ç¿ë Áö¼ö ¹æ¼öÁ¦ [1¾×Çü ¼öÆØÀ±¼º Æú¸®¿ì·¹Åº]
HYPERSEAL Á¾ÇÕ
°³ ¿ä
ÇÏÀÌÆÛ ¾ÁÀº ÁַΠƯ¼öÇÑ °í¹«·Î ¸¸µé¾îÁø Áö¼öÁ¦·Î¼­ ÀϹÝÀûÀÎ Áö¼öÆÇ º¸´Ù »ç¿ëÀÌ Æí¸®Çϰí Áö¼öÈ¿°ú°¡ ¸Å¿ì ¿ì¼öÇÏ´Ù. °í¹«ÀÇ Åº¼ºÀº ±¸Á¶¹°ÀÇ °áÇÕºÎÀ§ÀÇ ¼ö¹ÐÈ¿°ú¸¦ ÁÖ¸ç, ÀÌ´Â °áÇÕºÎÀ§ÀÇ ¹°ÁÙ±â ¹× »çÀ̰£°ÝÀ» ¿Ïº®È÷ ¾Á¸µ ÇÔÀ¸·Î½á ¿Ïº®ÇÑ Áö¼öÈ¿°ú¸¦ ³ªÅ¸³½´Ù.
´õ¿íÀÌ ÀÌ´Â °áÇÕºÎÀ§¸¦ ÅëÇØ Èê·¯µé¾î¿À´Â ¹°°ú Á¢ÃËÇϸé 2-10¹èÀÇ ÆØÃ¢Çö»óÀÌ ÀϾ ¼ö¹Ð¼ºÀ» ´õ¿í ³ôÇôÁØ´Ù. ¸ðµç Åä¸ñ°øÇÐ ¶Ç´Â Ư¼öÇÑ °ÇÃàÀ» Æ÷ÇÔÇÑ ¸ðµç °ÇÃàºÐ¾ß¿¡¼­ ´ç½ÅÀº ±â´ëÇÏÁö ¸øÇÑ Áö¼öÈ¿°ú¸¦ ¹ß°ßÇÒ ¼ö ÀÖ½À´Ï´Ù. ¿©±â¼­ ÀÚ»ç´Â ¸ðµç ÀÀ¿ëºÐ¾ß ¹× °¢°¢ÀÇ °ÇÃàÁ¶°Ç¿¡ ÀÀ¿ë °¡´ÉÇϵµ·Ï ´Ù¾çÇÑ Á¦Ç°À» Á¦Á¶Çϰí ÀÖ½À´Ï´Ù.
Ư ¡
¿Ïº®ÇÑ Áö¼ö : 2Áß ÀÛ¾÷¼ºÀ» ÅëÇÑ ¿Ïº®ÇÑ Áö¼ö¼º´ÉÀ» ³ªÅ¸³¿.
ÀÛ¾÷¾ÈÁ¤¼º : ź¼º°ú º¹¿øÀ» °í·ÁÇÏ¿© ±¸Á¶¹°ÀÇ º¯ÇüÀ» ½ÇÁúÀûÀ¸·Î ´Ù·ç¾ú´Ù.
ÀÀ¿ëÀÇ Æí¸®¼º : ½ÉÁö¾î Á»Àº °ø°£¿¡¼­ÀÇ ¿ëÀÌÇÑ ÀÛ¾÷¼ºÀ» À§ÇÏ¿© ¾î¶°ÇÑ ±¸Á¶¹°¿¡ ´ëÇØ¼­µµ ÁÁÀº Á¢Âø·ÂÀ» °®À¸¸ç °¡º±°Ô ÇÏ¿´´Ù.
±¤¹üÀ§ÇÑ ÀÀ¿ë¼º : ¾î¶°ÇÑ ³¯¾¾µç ¾î¶°ÇÑ ºÐ¾ßµç ÀÀ¿ëÀÌ °¡´ÉÇÏ´Ù.
¹Ý¿µ±¸ÀûÀÌ´Ù : Áö¼ÓÀûÀÎ ÆØÃ¢¼ºÀ» °®´Â´Ù.
Áö¼öÀÇ ¿ø¸®
¼öÆØÃ¢ Áö¼öÁ¦ÀÎ ÇÏÀÌÆÛ ¾ÁÀº Á¦Ç° ÀÚü°¡ Èí¼ö ÆØÃ¢ÇÏ¿© ±¸Á¶Ã¼ Á¢Ã˸鿡 ¹ÐÂøµÇ¾î Áö¼ö¼º´ÉÀ» ¹ßÈÖÇÑ´Ù.
¹° ¼º
Á¦Ç° Á¾·ù ¹° ¼º
Hardness (HS) Tensile Strength(kgf/cm2) Elongation (%) Expansion Rate by Volume (%) Expansion Rate by Volume in sea water (%)
DR
½Ã¸®Áî
45 ¡¾ 10 25 600 200 ~ 400 100 ~ 200
DP
½Ã¸®Áî
50 ¡¾ 10 - - 400 100
DS
½Ã¸®Áî
33 ~ 55 25 600 300 ~ 800 100 ~ 300

Á¦Ç° Á¾·ù ¹° ¼º
Specific Gravity Heat-resistance Test Cold-resistance Test Expansion Rate by Volume (%)
Variation Rate of Length Deformity of Appearance
DB
½Ã¸®Áî
1.35 ¡¾ 5% No Abnormality No Abnormality 400
BR
½Ã¸®Áî
1.2 ¡¾ 5% No Abnormality No Abnormality 50

Á¦Ç°ÀÇ Á¾·ù ¹× ¿ëµµ
¿ëµµ Á¦Ç°¸í ¹× ÇüÅÂ
(W x D mm)
Ư¡ ¹× ÁßÁ¡»çÇ× Æ÷Àå(Box)
°í¹« Áö¼öÁ¦
½Ã°øÀÌÀ½ºÎ DP-2010(20 x 10)
DR-2010
Note pre-expansion before secondary CON¡¯C cast 25M x 4 ROLL
DP-2010N(20 x 10)
DR-2010N
Restrain the expansion in length way by the insertion of a stainless net in case of pre-expansion 5M x 4 ROLL
DP-2010NH(20 x 10)
DR-2010NH
Needs sea water expansion in sea water area construction 25M x 4 ROLL
DP-2020(20 x 20)
DR-2020
The part with wide CON¡¯C 25M x 2 ROLL
½Ã°øÀÌÀ½ºÎ DP-2030(30 x 30)
DP-6030(60 x 30)
Choose the product that is 1.25 times or more as large as the expansion joint 50x50, 60x60 and other sizes are available by order 10M x 2 ROLL
10M x 1 ROLL
Shield TunnelSegment DS-2025(25 x 2)
DS-3020(20 x 3)
DS-4020-2.5C(20 x 4)
DS-6020-2.5C(20 x 6)
Specify the site condition in case sea water.Good corner adhesion, excellent durability and water pressure resistance 50M x 5 ROLL
25M x 8 ROLL
25M x 8 ROLL
15M x 8 ROLL
¼öÁ÷ÀÌÀ½ºÎ
½Ã°øÀÌÀ½ºÎ
DX-150
DX-230
Easy to deal with expansion joints floor mat connection part, vertical joint, the outer part of a double wall 30M/ROLL
20M/ROLL
Form Tie
Flat Tie
Others
DPR-012(ø 12)
DPR-318(18 x 3)
Ø7.5, ø16
Should be tight when inserting into a bolt. 2,000 EA
2,000 EA
º¥Å䳪ÀÌÆ® Áö¼öÁ¦
½Ã°øÀÌÀ½ºÎ
°ü½½¸®ºê
DB-2015(20 x 15)
DB-2520(25 x 20)
Specify the site condition in case sea water.
Excellent adhesion and easy to apply to rough surfaces.
Adhesive tape type(Prevention of sagging)
Need precaution against rainy time
10M x 4 ROLL
7.5M x 4 ROLL
Butyl seal
½Ã°øÀÌÀ½ºÎ BR-2507(25 x 7)
BR-2510(25 x 10)
Low expansion(50-70%)
Excellent adhesion and easy to apply to rough surfaces.
No change in physical properties in spite of Wet/Dry repetition.
20M x 4 ROLL
15M x 4 ROLL
1¾×Çü °æÈ­ Áö¼öÁ¦
Pipe sleeve,
H-shape Steel,
Crack Maintenance,
Expansion Joint,
Rib Lath Connection part
DPS-200
(Sealant Type)
Excellent adhesion; capable various application at any sites.
Even the irregular surfaces; Easy to apply
320 ml Cartridge
x 25PCS
½ÃÆ® ÆÄÀÏ¿ë Áö¼öÁ¦
½ÃÆ® ÆÄÀÏ¿ë DPS-1000(Liquid)
DPS-1000H(Liquid)
DPS-500(Liquid)
Temporary sheet pile
Sea water expanding is required at the sea water area construction.
Permanent sheet pile, Compleat sea water
20 kg PAIL
20 kg PAIL
20 kg PAIL
½Ã °ø ¿¹
½Ã°øÀÌÀ½ºÎ

¹ÙÅÁ¸éÁ¤¸® ÇÊ¿ä
ÁöÇϼö ¹× ¿ì¼ö¿¡ ´ëºñÇÑ º¸¾ÈÃ¥°­±¸
ÇØ¼öÁö¿ªÀº ÇØ¼öÆØÃ¢ÇÊ¿ä
¿¬°áºÎ´Â 5cm Áßø µÇ°Ô ½Ã°ø(DP-00XX)
½ÅÃàÀÌÀ½ºÎ

½ÅÃàÀÌÀ½ºÎÀ§º¸´Ù 25%ÀÌ»ó Å«sizeÀÇ Áö¼öÁ¦ »ç¿ë
keyȨ ¼³Ä¡ ÇÊ¿ä
Á¢ÂøÀç »ç¿ëÀ¸·Î µé¶ä Çö»ó ¹æÁö ÇÊ¿ä
º¹ÇÕÁö¼öÆÇ»ç¿ë (DX-00XX)
º¥Å䳪ÀÌÆ®Áö¼öÁ¦

°ÅÄ£¸é ½Ã°ø¿ì¼ö
Áö¼öÁ¦ ÀÚüÀÇ ¾Á¸µ È¿°ú Ź¿ù(DB-00XX)
Á¢Âø Tape¸¦ ºÎÂøÇÏ¿© ¼öÁ÷ÀÌÀ½ºÎ óÁü Çö»ó ¹æÁö
½¬Æ® ÆÄÀÏ¿ë

Àӽ𡼳¿ë(FSU-390)
¿µ±¸°¡¼³¿ë(FSU-390)
ÇØ¼ö¿ë ±¸ºÐ ÇÊ¿ä
°æ±âµµ ¾È»ê½Ã ¼º°îµ¿ 683-4 ½ÃÈ­°ø´Ü 6¹Ù505È£ ´ëÇ¥ÀüÈ­: 031-491-1611 ÆÑ½º: 031-491-7400
Copyright¨Ï 2001-2005 (ÁÖ)Çñ½ºÄÍ All rights reserved.